สายไฟโซล่าเซลล์และข้อต่อในระบบ

สายไฟโซล่าเซลล์และข้อต่อในระบบ

สายไฟโซล่าเซลล์และข้อต่อในระบ

Specifications

TUV certificationm
Simple,quick,safe and effective filed assembly
High mechanical endurance
Low transition resistance

C4 Cable Connector

Two Types

1—Cable standard:only 2.5/4mm2(14/12AWG)

2—Cable standard:only 4/6.0mm2(10AWG)

 

MC4 Solar Connector with TUV

 

Rated current :  30A(2-4mm²) Degree of protection: IP2*/IP67
Retaed voltage:   1000V DC Flame class  :  UL94-V0
Test voltage:     6000V(50Hz,1min) Safety class:     II
Overvoltage category:CATIII Suitable class:   OD4.5-7.0(2.5-4.0mm²)
Contact resistance of plug connectosr: 0.5mΩ Insertion force/withdrawal force: ≤50N/≥50N
Contact material: Copper,Tin Plated Connecting System: Crimp connection
Insulation material : PPO Temperature range: -40~+90 degree

The pictures for Assemble the cable and connector as follow:

 

MC4 Solar Connector with TUV MC4 Solar Connector with TUV MC4 Solar Connector with TUV MC4 Solar Connector with TUV

MC4 connector and accessories

MC4 Solar Connector with TUV

SOLAR MC4 CONNECTOR ข้อต่อ MC4_SERIES

Solar MC4 connector  ข้อต่อ MC4_Series

ข้อต่อโซล่าเซลล์ MC3

Specifications

TUV certificationm
Simple,quick,safe and effective filed assembly
High mechanical endurance
Low transition resistance
 

Rated current :  30A(2-4mm²) Degree of protection: IP2*/IP67
Retaed voltage:   1000V DC Flame class  :  UL94-V0
Test voltage:     6000V(50Hz,1min) Safety class:     II
Overvoltage category:CATIII Suitable class:   OD4.5-7.0(2.5-4.0mm²)
Contact resistance of plug connectosr: 0.5mΩ Insertion force/withdrawal force: ≤50N/≥50N
Contact material: Copper,Tin Plated Connecting System: Crimp connection
Insulation material : PPO Temperature range: -40~+90 degree

ชุดคีมงานสายไฟโซล่าเซลล์CRIMPING

สายไฟโซล่าเซลล์ 2.5mm/4mm/6mm

 

Technical Data

 

Cross section (mm2) Conductor construction (n/mm) Conductor Stranded OD.(mm) InsulationMin.Wall Thickness(mm) SheathMin.Wall Thickness(mm) Cable OD.(mm) Conductor Max.Resistance AT 20°C( Ω/km) Current Araaing Capacity AT 60°C(A)
1×1.5 30/0.25 1.58 0.67 0.73 4.90 13.3 30
1×2.5 49/0.25 2.02 0.67 0.73 5.45 7.98 41
1×4.0 56/0.30 2.60 0.67 0.73 6.10 4.95 55
1×6.0 84/0.30 3.42 0.80 0.80 7.20 3.30 70
1×10 84/0.40 4.56 0.90 0.90 9.00 1.91 98
1×16 128/0.40 5.60 1.00 0.90 10.20 1.21 132
1×25 192/0.40 6.95 1.19 0.92 12.00 0.78 176
1×35 276/0.40 8.74 1.20 1.00 13.80 0.554 218
Drawing  

 

Description

 

 

1.Rating:Voltage: 600/1000V  Temperature:-40°C– 90°C

 

2. Description: (1)Conductor:  Tinned annealed  copper

 

(2)Insulation:120°C  XLPE , black

 

(3)Jacket:120°C  XLPE , black or red

 

3.Marking:TÜV  2  PfG  1169  PV1-F  1×**mm2

 

4.Application: Specifically designed for connecting photovoltaic system components inside and outside of building and equipment  with high mechanical requirements and extreme weather conditions .For permanent installations.

 

5.General characteristics: Cable made of electron-beam cross-linked insulation and coating; high resistance against heat , cold, oil, abrasion, ozone, UV and weather; with improved reaction in case of fire . low smoke, halogen free , flame free , flame retardant; flexible, easy to strip, very low space requirement,  extremely, extremely mechanically robust, very long lifetime.

 

 

 

MC4 connector and accessories